On the evening of 18 November 1987, a fire started beneath a wooden escalator at King's Cross Underground station in London. 31 people died, including Station Officer Colin Townsley of the London Fire Brigade, who was found beside a passenger he had been trying to help.

An ordinary cause

The cause was ordinary. The Piccadilly line escalators dated from 1939 and were built largely of plywood. Grease and debris had built up on the running tracks beneath the steps, and the public inquiry found the tracks had never been cleaned completely.

Despite a smoking ban, a lit match fell through a gap beside the steps into that build up.

About 20 minutes

It started at about 7.25pm. Between 7.43pm and 7.45pm, flames erupted from the escalator shaft into the ticket hall, which was still busy with the evening rush hour.

By everything understood at the time, a fire like that should not have grown so fast. Explaining it fell to the public inquiry led by Sir Desmond Fennell.

The trench effect

Slide showing 30 degrees: the escalator sat in a trench sloped at 30 degrees and the flames lay down along the incline.

The answer came from computer modelling at Harwell and fire tests on scale models run by the Health and Safety Executive. They identified what is now called the trench effect.

The escalator sat in a trench inclined at 30 degrees. Once established, the flames lay down along the trench instead of rising, heating the steps ahead. Air could no longer reach the uphill side of the flames, and the fire switched into a far more intense mode, driving flame and hot gases up the incline and into the ticket hall.

The report said the investigation had "extended the boundaries of scientific knowledge".

What changed afterwards

The 1988 report made 157 recommendations, including replacing wooden escalators, extending the smoking ban to all station areas and improving radio communications for firefighters working underground.

New fire precautions regulations for underground stations followed in 1989, covering means of escape, fire detection and warning, and the materials used inside stations.

What it still teaches

King's Cross changed how engineers think about fire in sloped and enclosed spaces. A fire's behaviour depends on the geometry around it, not just what's burning.

A fire's behaviour depends on the geometry around it, not just what's burning.

And the conditions that made it possible, the old materials and the debris under the steps, were in places nobody looked once the escalators were in service.